Capillary Manometers

Capillary Manometers

Technical Specifications:
 
Usage Features  Standard
Measurement Range         0 - 100      0 - 16    0 - 25        
 bar 0 - 40        0 - 60    0 - 100     bar
0 - 160     
Diaphragm Stainless AISI-316
Process Connection Stainless  AISI-316

Processing Temperature -40... +200 °C
Pressure Range 0/100...0/100 bar
Work   (Max.) A maximum of 75% of the Full Cipher Value must not exceed.
Over Pressure Limit PN x 1,25
Sensitivity Class KL 1,0
Relevance DIN / ANSI
Optimum Measurement Range 0,1 PN ile 0,75 x PN between
Protection Class IP 41
Storage Temperatures -40 ... +70°C
Mechanical Shock Test Load 15 g
Mechanical Vibration Test 10 Hz ile 150 Hz - 1 oktav/dk.2s / 3 axis
 

♦ Places of Use: Suitable for corrosive, dirty, high temperature and density fluid media.