Standard Electrical Contact Manometers

Standard Electrical Contact Manometers

 Technical Specifications:
Usage areas Standard 
Mounting Type Subnet Linked
Measurement unit bar
Measurement Range  0 - 0,6 0 - 1   0 - 1,6 0 - 2,5  0 - 4
 0 - 6     0 - 10  0 - 16 0 - 25  0 - 40
 0 - 60  0 - 100   0 - 160    
         
Body  Stainless  AISI-304 
Cover  Stainless  AISI-304 
Appearance Plate Acrylic
Mechanism Rice 
Pressure Organ  Copper Alloy
Connection   G  1/2’’  B
Dial Aluminum
Hand Aluminum
Merge Source Solder
Vacuum Measurement Range   -1 / 0 -1,6666667  -1 / +1,5  -1 / +3
bar  -1 / +9  -1 / +15   -0,0416667  
mmHg   -760 / 0      

Fluid Temperature  maxsimum + 60 °C  maxsimum + 120 °C
Ambient temperature - 20 ... + 60 °C
Operating pressure (max.) The full scale value must not exceed a maximum of 75%.
Over Pressure Limit ≤40 bar PN x 1.25           >40 bar PN x 1.15
Sensitivity Class KL 1.0
Relevance EN 837 - 1
Optimum Measurement Range 0,1 x PN ve 0,75 x PN between
Protection Class IP 65
Storage Temperatures -40 ... +70 °C
Mechanical Shock Test Load 15g
Mechanical Vibration Test 10 Hz ile 150 Hz -1 oktav/dk. 2s / 3 axis
 

Applications:Oil, Chemical, petroleum and food processing plants, nuclear and natural gas power plants, etc. used in areas..